我是房东,因为租客说开空调有个别灯闪,中介安排了电工去修。
但电工去的时候空调 安防 和 灯都是能正常工作,当电工换了完开关后,说家好很多射灯 灯 中央空调( 三项电) 还有安防烧了。
已经和中介争执了两天了,中介说因为是天冷必须马上把空调这些修好,还有给房客减租,电工没有责任,让我们同意去维修这些,如果不认可自己去地方投诉去。
下面是中介转发电工的,大家帮忙看看 ,出出主意,我这是谁的责任,我应该怎么办。 谢谢
What was the issue?
Lights flickering, dimming. Not working.
main switch was faulty and sparking on one of the terminals. This terminal fed the lights and other circuits. There appeared to be a fault in the switchboard and the main switch popped once reset.
What did we do?
Install new main switch
Was there any extras/variations?
When I turned everything back on the AC and some lights weren’t working.
8 transformers had blown so I replaced all transformers, 12V cables and halogen globes.
Another 4 globes had just blown so I changed them over as well.
the AC wasn’t working. It had correct voltage at circuit breaker. Went to isolator and white phase terminal had no continuity so I changed over to a brand new isolator. the inside control pad still does not work.
----------------------------------------------
The original job we attended was for lights flickering at the property. NXXXXX attended and found an arcing sounds coming from the main switch in the switchboard. It was a pulset branded main switch which we find to fail fairly regularly.
Nathen went to turn the main switch off and it popped and sparked. At this point Nathen isolated the supply and replaced the main switch.
Once he reenergised supply and turned the main switch on there were a few issues. The downlight transformers had blown in around 13 downlights. The A/C was not working. The security system was not working.
After further investigation we found a surge protective resistor in the outdoor unit of the A/C was blown. We also found the security system had burn marks and a blown PCB.
I believe that when the main switch failed it shorted between two of the phases causing a surge and increased voltage across two phases of the installation.
Moving forward we will need to potentially replace downlights, replace the A/C control boards and replace the security system printer circuit board.
I can't see a circumstance that NXXXXX could have created to have the damage listed above and want to make it clear that this was the result of the faulty main switch.
评论
这个很难判断是电工的过错,但可能性是有的
所有电器都是过电压烧坏了
评论
这个电工没执照吧?这些都在电工保险里cover
评论
如果是三相电 很可能是 电工忘了接 总零线使电压变成415v 才会烧所有电器
评论
瞎七搭八,哪来的过低压。其实人家已经说清楚了,由于时间长了,有些电线接头松动,造成接头烧枯,接触不好。检查需要时间,人力,有些接头要换,当然要算钱。小毛病,化时间
评论
楼主说的所有新故障,只是接头氧化,接触不好造成的。不管是电工或者任何人,敲敲这块板都会这样。我建议楼主照电工建议做,以绝后患
评论
无事生非,小事化大。不然怎么赚钱?同样一个电工,给个人和给公司/strata干收费差太多了。
评论
Fair trading, 简单。
评论
是三项电,这个能找其他电工鉴定出他是否有操作问题吗?
评论
是有牌电工 但他们并不打算赔偿
评论
让中介给你修东西都是找死
评论
当时房子还有三项10kw太阳能在发电,如果当时电工先关闭了其他分路开关和太阳能开关。在去处理主开关,会不会能避免这些事发生
评论
看看建筑保险的条款会cover不
评论
???? 我们的房屋保险安联的不包括电器烧毁
后悔啊
评论
这种中介留着过年吗,休了
澳洲中文论坛热点
- 悉尼部份城铁将封闭一年,华人区受影响!只能乘巴士(组图)
- 据《逐日电讯报》报导,从明年年中开始,因为从Bankstown和Sydenham的城铁将因Metro South West革新名目而
- 联邦政客们具有多少房产?
- 据本月早些时分报导,绿党副首领、参议员Mehreen Faruqi已获准在Port Macquarie联系其房产并建造三栋投资联