我的需求是替换之前的旧线路,从20amp升级到40amp,加三组共六个插孔,不包挖地,收到两个报价,华人师傅上门看过报价$3886 这么多米
Description Qty Rate (ex tax) Amount (ex tax)
UniLine MCB 6kA 1 Pole 40A C-Curve
(Supply and Fit with STD Access, without any extra cables or modification)
1 $171.82 $171.82
CONDUIT PVC RIGID HEAVY DUTY 40MM 4M ORANGE
(Supply and Fit with either on the wall, or in the cavity, or underground)
10 $50.00 $500.00
CABLE ORANGE CIRCULAR 6MM 7/104 2C+E ORANGE SHEATH
(Supply and Fit with either in the cavity or in Conduit)
40 $40.91 $1,636.36
CONDUIT 90DEG LRG SWEEP BEND 40MM
(Supply and Fit with either on the wall, or in the cavity, or underground)
2 $31.82 $63.64
IP56 Junction Box with Gasket 100 x 100 x 75mm
(Supply and Fit with either on the wall, or in the cavity, or underground)
1 $68.18 $68.18
Plain to Screw Adapter with lock ring 40mm
(Supply and Fit with either on the wall, or in the cavity, or underground)
1 $31.82 $31.82
Voltex Classic Double Power Outlet 250V 10A
(New Installation with Standard access, installation with cable in wall or in coundit)
3 $153.64 $460.91
MOUNTING BLOCK 1 GANG STANDARD
(Supply and Fit with either on the wall, or in the cavity, or underground)
3 $18.18 $54.55
CONDUIT PVC RIGID MEDIUM DUTY 25MM 4M GREY 1 $22.73 $22.73
Miscellaneous - Timber and Screws 1 $90.91 $90.91
UniLine Single Module RCBO 1P+N 6kA C-Curve 10A 30mA
(Supply and Fit with STD Access, without any extra cables or modification)
1 $117.27 $117.27
UniLine Single Module RCBO 1P+N 6kA C-Curve 20A 30mA
(Supply and Fit with STD Access, without any extra cables or modification)
2 $117.27 $234.55
Surface Cover - 4 way
(Supply and Fit with STD Access, without any extra cables or modification)
1 $80.00 $80.00
SUBTOTAL $3,532.74
GST (10%) $353.26
评论
另一个师傅看图报价,$2200+GST,只管铺,不包挖和埋:
price is
2200+g
Details
1. 6mm cabling with conduit work according to the fense from switchboard to new subboard in the shed(no digging and no underground, just only surface conduit work on the fense side)
2. Install small enclosure in the shed
3. Install 2x submain switch in both side, 2 x safety switches on the new board for power circuits
4. Install 6 x weather proof power points in the shed.
Ps. You have to dig in entry point near the old switchboard to the fense and also from the fens, to the shed. After conduit work, you have to put back soil.
if u can dig and get back we can do underground cabling with conduit.
评论
完全看不懂 隔行如隔山哪,请大神们帮看下。
评论
找洋人电工试试看,我感觉高了些,我今年要拉28米地下线,槽是25年前挖的,需要重新手工挖开,另外要重新挖条水管,也在问价,到时候交流交流。
评论
重新挖壕沟就是贵,贵多贵少就是了。你要想的话也可以另外请人挖填。