新西兰ventilation compliance
在新西兰
请教各位大神,一个旧房子出租,health 检查说,bathroom 和 kitchen的 ventilation 不合格,这个是要在厨房厕所装换气扇,还是可以装浴霸和排油烟机就行。谢谢
评论
你都检查过了, 检查那人不会跟你说要做什么的么? 来这问啥。。。
评论
只有报告,没有改进工作,不懂英文
评论
Bunnings 买个风扇带灯的那种 买管子 找电工帮你装上就行
评论
好的,了解了,谢谢你的帮助
评论
Kitchens and bathrooms must have extractor fans.
Mould and dampness caused by poor ventilation is harmful for tenants’ health as well as landlords’ property. The ventilation standard targets mould and dampness in rental homes.
Kitchens – In any room with a cooktop, new fans or rangehoods installed after 1 July 2019 must have a minimum diameter (including ducting) of 150mm or an exhaust capacity of at least 50 litres per second.
Bathrooms – In any room with a shower or bath, new fans installed after 1 July 2019 must have a minimum diameter (including ducting) of 120mm or an exhaust capacity of at least 25 litres per second.